Skip Navigation



European Journal of Echocardiography Advance Access published online on July 16, 2008

European Journal of Echocardiography, doi:10.1093/ejechocard/jen196
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/1/144    most recent
jen196v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Schwagten, B.
Right arrow Articles by Szili-Torok, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schwagten, B.
Right arrow Articles by Szili-Torok, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org

Baffle puncture guided by transoesophageal echocardiography in a patient with dextrocardia and Mustard correction

B. Schwagten*, L. Jordaens, E. Jessurun, M. Witsenburg, M. Scheffer and T. Szili-Torok

Department of Cardiology, Thoraxcenter, Erasmus Medical Center, Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands

* Corresponding author: Tel: +31 107040704. E-mail address: t.szili-torok{at}erasmusmc.nl


   Abstract

A baffle puncture is a challenging procedure but can be safely done using direct visualization of the region of interest. To our knowledge, however, it has never been performed in a patient with dextrocardia. We present a 62-year-old male with dextrocardia, right isomerism, congenitally corrected transposition of the great arteries, persistent left-sided superior and inferior caval veins, atrial septum defect, and pulmonary valve stenosis. The atrial septum defect was surgically closed with a Teflon® patch, a variant Mustard operation was performed, and also a prosthetic tricuspid valve was implanted. The patient developed multiple episodes of atrial tachycardia leading to acute heart failure on many occasions. An electrophysiological study was undertaken in order to create a bi-atrial electro-anatomical map. Owing to the presence of a prosthetic tricuspid valve, the femoral venous access was used and a baffle puncture was performed using continuous monitoring with fluoroscopy and transoesophageal echocardiography (TEE). The baffle puncture was successful and the tachycardia was ablated in the systemic venous atrium. To our knowledge, we present the very first case report demonstrating a successful baffle puncture in a patient with dextrocardia and Mustard correction. Direct imaging using TEE seems to be a very useful tool for guiding the puncture.

Keywords: Dextrocardia; Baffle puncture; Transoesophageal echocardiography


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.