Skip Navigation



European Journal of Echocardiography Advance Access published online on June 10, 2008

European Journal of Echocardiography, doi:10.1093/ejechocard/jen178
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Supplementary Data
Right arrow All Versions of this Article:
9/6/822    most recent
jen178v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Acar, P.
Right arrow Articles by Elbaz, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Acar, P.
Right arrow Articles by Elbaz, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org

Real-time 3D transoesophageal echocardiography for guiding Amplatzer septal occluder device deployment in an adult patient with atrial septal defect

Philippe Acar*, Pierre Massabuau and Meyer Elbaz

Congenital Heart Unit, Rangueil Hospital, Toulouse, France

Received 11 March 2008; accepted after revision 18 May 2008.

* Corresponding author: Cardiologie Pédiatrique, Hôpital des enfants, 330 Av de grande-bretagne, Toulouse 31130, France. Tel: +33 5 34 55 87 15; fax: +33 5 34 86 63. E-mail address: acar.p{at}chu-toulouse.fr


   Abstract

A 32-year-old male with secundum atrial septal defect underwent percutaneous transcatheter occlusion. The procedure was performed under general anaesthesia and guided by real-time 3D transoesophageal echocardiography (TEE) (i.e. 33, matrix probe 2–7 MHz). The device delivery system was advanced through a femoral vein catheter and placed in the left upper pulmonary vein. A 3D left atrial view was instantaneously obtained. The size of the septal occluder was chosen according to the balloon catheter method. A 12 mm Amplatzer device was deployed under real-time 3D TEE without fluoroscopy. The 3D views depicted the progression of the left-side disc from the left atrial cavity towards the septum. Left and right atrial views demonstrated the perfect application of the device to the atrial septum. Keeping a steady traction on the delivery rod, the right-side disc of the device was then deployed on the right atrial side of the defect. A pushing and pulling of the delivery cable ensured that the device was in a secure and stable position. Absence of periprothetic residual shunt was assessed by 2D colour Doppler TEE before release. Transthoracic echocardiography performed the day after ensured the right position of the device. Real-time 3D TEE is a very recent technology allowing on-line guidance of atrial septal occluder device deployment; such imaging should increase delivery safety and decrease fluoroscopy time.

Keywords: 3D echocardiography; Atrial septal defect; Transoesophageal echocardiography; Amplatzer occluder


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
J. A. Lodato, Q. L. Cao, L. Weinert, L. Sugeng, J. Lopez, R. M. Lang, and Z. M. Hijazi
Feasibility of real-time three-dimensional transoesophageal echocardiography for guidance of percutaneous atrial septal defect closure
Eur J Echocardiogr, June 1, 2009; 10(4): 543 - 548.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.