Skip Navigation



European Journal of Echocardiography Advance Access published online on May 1, 2008

European Journal of Echocardiography, doi:10.1093/ejechocard/jen146
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
9/6/779    most recent
jen146v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Bajraktari, G.
Right arrow Articles by Henein, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bajraktari, G.
Right arrow Articles by Henein, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org

Prolonged total isovolumic time predicts cardiac events following coronary artery bypass surgery

Gani Bajraktari1, Alison Duncan2, John Pepper2 and Michael Henein3,*

1 Second Division of Cardiology, University Clinical Centre of Kosova, Prishtina, Kosovo
2 Royal Brompton Hospital, London, UK
3 Umea Heart Centre, Umea University, Sweden

Received 19 December 2007; accepted after revision 21 March 2008.

* Corresponding author. Tel: +46 90 7851428; fax: +46 90 137633. E-mail address: henein{at}googlemail.com


   Abstract

Aims: Left ventricular (LV) systolic dysfunction may be associated with compromised stroke volume, which may be caused by asynchrony, reflected on the prolongation of isovolumic time (t-IVT). To assess the prognostic role of Doppler echocardiographic measurements in predicting cardiac events after coronary artery bypass grafting (CABG).

Methods and results: The study included 74 patients undergoing routine CABG. A pre-CABG Doppler echocardiographic assessment of LV dimensions, filling and ejection was performed and t-IVT was determined as [60 – (total ejection time + total filling time)]. Follow-up period was 18 ± 12 months. Of the 74 patients (age 65 ± 16 years, 59 males), 29 underwent hospital admission for a cardiac event or died. There were no differences in age, gender, incidence of previous infarct or mitral regurgitation, LV-EDD (left ventricular end-diastolic dimension), left atrial or right ventricular size in patients with cardiac events compared with those without events. Left ventricular end-systolic dimension (LV-ESD) was greater (4.5 ± 0.9 vs. 3.9 ± 0.9 cm, P = 0.003), fractional shortening (FS) was lower (21 ± 4 vs. 32 ± 8%), E:A ratio and Tei index were higher (2.1 ± 0.8 vs. 1.0 ± 0.6 and 0.9 ± 0.3 vs. 0.6 ± 0.3, all P < 0.001), and t-IVT was longer (16 ± 5 vs.10 ± 4 s/min, P < 0.001) in patients with events. Multivariate predictors of post-CABG events (odds ratio 95% confidence interval) were low FS [0.66 (0.50–0.87), P < 0.001], high E:A ratio [l4.13 (1.17–14.60), P = 0.028], large LV-ESD [0.19 (0.05–0.84), P = 0.029], and long t-IVT [1.37 (1.02–1.84), P = 0.035].

Conclusion: Despite satisfactory surgical revascularization, long t-IVT and systolic dysfunction suggest persistent ventricular dyssynchrony that contributes to post-CABG cardiac events. Early assessment of such patients for potential benefit from electrical resynchronization may optimize their cardiac performance and hence clinical outcome.

Keywords: Coronary artery disease; Coronary artery bypass grafting; Doppler echocardiography; Total isovolumic time


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.