European Journal of Echocardiography Advance Access published online on April 21, 2008
European Journal of Echocardiography, doi:10.1093/ejechocard/jen144
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org
A case of acute heart failure due to giant aortic pseudoaneurysm with fistulization to the right ventricle after a modified Bentall operation
Rui Almeida*,
Teresa Pinho,
Nuno P. Oliveira,
Jorge Almeida,
Filipe Macedo,
António R. Sousa and
M. Júlia Maciel
Department of Cardiology, Hospital S. João, Alameda Prof. Hernâni Monteiro, 4200-319 Porto, Portugal
Received 6 December 2007; accepted after revision 21 March 2008.
* Corresponding author. Tel: +35 1962450952. E-mail address: ruitalmeida{at}netcabo.pt
 |
Abstract
|
|---|
Simultaneous en bloc replacement of the ascending aorta and
aortic valve by a composite valve graft, as first described
by Bentall and De Bono in 1968 and with later modifications,
has become the standard surgical technique in the treatment
of aneurysms of the aortic root associated with severe aortic
valve dysfunction. Despite the good surgical results overall,
it is still associated with considerable perioperative mortality
and with dire complications in the long run. We report a case
of a giant aortic pseudoaneurysm compressing the right heart
chambers and communicating with the right ventricle presenting
as rapidly progressing heart failure a few months after a Bentall
operation.
Keywords: Aortic pseudoaneurysm; Bentall operation; Acute heart failure
A 49-year-old obese male patient with annuloaortic ectasia associated
with a bicuspid and severely regurgitant aortic valve underwent
a modified Bentall operation with insertion of a 25 mm St Jude
composite valve graft (CVG) and re-implantation of the coronary
arteries using the button technique in our institution.
He had an uneventful recovery and was discharged on warfarin
and a beta-blocker.
Five months later, he was re-admitted with acutely decompensated heart failure that had progressed over the week before. He complained of dyspnoea, orthopnoea, abdominal swelling, and low urinary output and presented with respiratory distress, lung congestion, distended neck veins, and peripheral oedema. Cardiac auscultation revealed a grade 2/6 systolic ejection murmur over the left sternal border and aortic area. The International normalized ratio on admission was 1.97. The chest X-ray showed enlargement of the mediastinum and cardiac silhouette with a prominent right border. The 12-lead electrocardiogram showed sinus rhythm and non-specific repolarization abnormalities in the inferior and left pre-cordial leads. The transthoracic echocardiogram showed normal-sized heart chambers with preserved left ventricular systolic function, a normal functioning bileaflet aortic prosthetic valve, and the presence of a large vascular structure anterior to the aortic graft and extending inferiorly, compressing the free wall of the right ventricle (Figure 1A–C and Supplementary data online, Videoclip S1). A communication between the graft and mass could not be identified, but the presence of a continuous but predominantly diastolic flow from the structure to the right ventricular chamber at its apex was noted (Figure 2A and B and Supplementary data online, Videoclip S2). Adding up to these data, the use of echocontrast agent injected in a peripheral vein suggested the presence of a left-to-right shunt by showing sequential opacification of the right heart chambers, left heart chambers, and vascular structure (Figure 3A–C). In order to establish the origin of the mass, a cardiac catheterization was performed. It confirmed the presence of a large para-aortic vascular structure extending anteriorly and inferiorly adjacent to (and compressing) the right ventricle. The structure was shown to communicate with the tubular graft by an opening at the level of the implantation of the right coronary button (Figure 4A and B). A communication between the mass and the right ventricle was not visible in the study, but there was an estimated pulmonary-to-systemic flow ratio of 1.6 (using the Fick method), suggesting the presence of a left-to-right shunt. Diagnosis of a large pseudoaneurysm originating from the suture line of the implantation of the right coronary artery in the tubular aortic graft compressing and communicating with the right ventricle was established as the cause of the clinical presentation and the patient was transferred to the Cardiothoracic Surgery Department for urgent surgical treatment. A femoro-femoral cardiopulmonary bypass was instituted and the patient cooled down to about 23°C of oesophageal temperature. As soon as the sternum was opened, the pseudoaneurysm lying right behind it immediately ruptured. Oxygenated blood coming from the right coronary button's anastomosis could be seen; a tear in the suture line was identified and carefully sewn. The orifice in the right ventricular free wall was closed with a Teflon patch. Pathology from the resected tissue showed fibro-sclerotic material with fibrinoid deposition and foci of haemorrhage, with no signs of infection. The patient had an uneventful recovery and was discharged after 13 days.

View larger version (38K):
[in this window]
[in a new window]
[Download PowerPoint slide]
|
Figure 1 (A–C) Transthoracic echocardiogram showing a large mass, marked with an asterisk (*), anterior to the aortic graft and compressing the right ventricle, in parasternal long axis (A), parasternal short axis (B), and apical four-chamber (C) views.
|
|

View larger version (62K):
[in this window]
[in a new window]
[Download PowerPoint slide]
|
Figure 2 (A) Colour flow Doppler in apical four-chamber view showing flow between the mass and right ventricular apex (arrow). (B) Pulsed wave spectral Doppler in the same view suggesting continuous but predominantly diastolic flow from the mass to the right ventricle.
|
|

View larger version (43K):
[in this window]
[in a new window]
[Download PowerPoint slide]
|
Figure 3 (A–C) Apical four-chamber view echocardiogram after intravenous injection of echocontrast agent showing sequential opacification of right ventricle (A), left ventricle (B), and vascular mass (C), which appear to communicate with the right ventricular chamber at its apex (*).
|
|

View larger version (74K):
[in this window]
[in a new window]
[Download PowerPoint slide]
|
Figure 4 (A and B) Left anterior oblique view of angiogram of the aortic graft. (A) Leak of contrast can be seen from the graft lumen at the implantation of the right coronary button (white arrow). Flow to the right coronary artery was not compromised (black arrow). (B) A pig-tail catheter was inserted in the pseudoaneurysm and contrast agent was injected, showing its large multilobed contour extending both upward and antero-inferiorly from its origin.
|
|
 |
Discussion
|
|---|
After earlier attempts at separate repair of the aortic valve
and ascending aorta with a high incidence of bleeding complications
at the suture lines, the use of en bloc replacement of both
structures by a CVG, as described by Bentall and De Bono
1 nearly
40 years ago, became the procedure of choice in the treatment
of disease of the aortic valve, aortic root, and ascending aorta.
Later modifications of the procedure, including re-implantation
of the coronary arteries on the graft using the button
technique
2 and better strategies of myocardial and cerebral
protection have improved outcomes.
3
Recently published series of patients submitted to the modified Bentall operation have shown favourable results, with 30-day mortality rates ranging from 0.7 to 6.9% and 5-year actuarial survival rates of 77.7 to 95%.3–5 However, major complications in the medium and long term may occur, including (i) progression of disease in the native aorta with recurrent aneurysm, dissection, and rupture; (ii) prosthetic valve infection and dysfunction; and (iii) complications involving the prosthetic conduit.6
Pseudoaneurysms originating from dehiscence of suture lines are one of the most feared and lethal complications of the operation. They usually evolve insidiously and unnoticed or with non-specific findings, as an early or late complication, until they cause serious life threatening conditions, namely compression of the cardiac chambers and nearby structures, major thrombo-embolic events or rupture (either free rupture or fistulization into various structures). The incidence of pseudoaneurysms after CVG implantation as reported in the literature varies from 0 to 39%, reflecting different practices in follow-up surveillance and selection bias.5,7–9 Risk factors associated with its occurrence include suture line tension, infection, excessive anticoagulation, and underlying disease (with worse results reported in cases of Marfan syndrome and after correction of aortic dissection).2,9
Pseudoaneurysms complicating CVGs may originate in three different sites: (i) proximal anastomosis at the aortic annulus; (ii) distal anastomosis between graft and native aorta; and (iii) implantation site of the coronary arteries.10 Several imaging modalities have been reported to be useful in their diagnosis, including aortography,11 transthoracic (TTE) and transoesophageal echocardiography (TEE),8,10 computed tomography,12 and magnetic resonance imaging13 and they often complement each other. TEE with Doppler has become the modality of choice in this context, due to its ready availability and higher accuracy than TTE in identifying the presence of pseudoaneurysms and their sites of origin, by showing an area of flow extending a variable distance beyond the aortic lumen into an echo-free space surrounding the aortic graft, often partially filled by echodense masses corresponding to extravascular thrombus.10,14
Our case of a giant aortic pseudoaneurysm complicating a previous Bentall procedure had the unusual finding of fistulization to the right ventricle, which has not, to our knowledge, been previously reported in the literature. We were unable to either establish the cause of the giant structure or identify flow from the aortic lumen into it by conventional Doppler TTE and TEE was not readily available, but fistulization into the right ventricle was observed and the use of contrast was helpful in suggesting the diagnosis. Cardiac catheterization with aortography was also important in showing the origin of the pseudoaneurysm from the right coronary button and confirming the already suspected left-to-right shunt. It illustrates the complementary role of the available imaging techniques in the accurate assessment and follow-up of these patients.
 |
Supplementary data
|
|---|
Supplementary data is available at
European Journal of Echocardiography online.
 |
References
|
|---|
- Bentall H, De Bono A. A technique for complete replacement of the ascending aorta. Thorax (1968) 23:338–9.[Abstract/Free Full Text]
- Kouchoukos NT, Wareing TH, Murphy SF, Perillo JB. Sixteen-year experience with aortic root replacement. Results of 172 operations. Ann Surg (1991) 214:308–20.[Web of Science][Medline]
- Hagl C, Strauch JT, Spielvogel D, Galla JD, Lansman S, Squitieri R, et al. Is the Bentall procedure for ascending aorta or aortic valve replacement the best approach for long-term event-free survival? Ann Thorac Surg (2003) 76:698–703.[Abstract/Free Full Text]
- Pacini D, Ranocchi F, Angeli E, Settepani F, Pagliaro M, Martin-Suarez S, et al. Aortic root replacement with composite valve graft. Ann Thorac Surg (2003) 76:90–8.[Abstract/Free Full Text]
- Gelsomino S, Morocutti G, Frassani R, Masullo G, Da Col P, Spedicato L, et al. Long-term results of Bentall composite aortic root replacement for ascending aortic aneurysms and dissections. Chest (2003) 124:984–8.[CrossRef][Web of Science][Medline]
- Fadel BH, Abdulbaki K, Nambiar V, Al Amri M, Hasan W, Shahid M, et al. Aortic pseudoaneurysm with fistulization into the pulmonary artery: a cause of refractory Herat failure alter Bentall procedure. J Am Soc Echocardiogr (2007) 20:438.e5–8.
- Ballal RS, Gatewood RP, Nanda NC, Sanyal RS, Kirklin JK, Pacifico AD. Usefulness of transesophageal echocardiography in the assessment of aortic graft dehiscence. Am J Cardiol (1997) 80:372–6.[CrossRef][Web of Science][Medline]
- Chu J, Chang J, Lin PJ, Chang CH. Composite graft tear and aortico-left ventricular tunnel after aortic root replacement using Cabrol's technique. J Formos Med Assoc (2000) 99:170–3.[Web of Science][Medline]
- LeMaire SA, DiBardino DJ, Köksoy C, Coselli JS. Proximal aortic reoperations in patients with composite valve grafts. Ann Thorac Surg (2002) 74:S1777–80.[Abstract/Free Full Text]
- Barbetseas J, Crawford ES, Safi HJ, Coselli JS, Quinones MA, Zoghbi WA. Doppler echocardiographic evaluation of pseudoaneurysms complicating composite grafts of the ascending aorta. Circulation (1992) 85:212–22.[Abstract/Free Full Text]
- Nath PH, Zollikofer C, Castaneda-Zuniga WR, Velásquez G, Formanek A, Nicoloff D, et al. Radiological evaluation of composite aortic grafts. Radiology (1979) 131:43–51.[Abstract]
- Omeroglu SN, Mansuroglu D, Goksedef D, Cedat Y. Ultrafast computed tomography in management of postbentall aortic root pseudoaneurysm repair. Tex Heart Inst J (2005) 32:91–4.[Web of Science][Medline]
- Gilkeson RC, Clampitt MS, Stewart RM, Laden NS. Pseudoaneurysm of aortic cannulation site after coronary artery bypass grafting: evaluation with gadolinium enhanced MR angiography. Am J Roentgenol (1999) 172:843–4.[Web of Science][Medline]
- Quin EM, Kerut EK, Brown AP, Fox ER. Aortic pseudoaneurysm of a Bentall composite valve graft associated with acute cocaine ingestion. Echocardiography (2006) 23:886–9.[CrossRef][Web of Science][Medline]