Skip Navigation

European Journal of Echocardiography 2006 7(2):175-176; doi:10.1016/j.euje.2005.04.001
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Aggeli, C.
Right arrow Articles by Stefanadis, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aggeli, C.
Right arrow Articles by Stefanadis, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2005, The European Society of Cardiology

Acute thoracic aortic thrombosis after intra-aortic balloon pumping

Constadina Aggeli, Vassilis I. Barberis*, Charalambos Vlachopoulos, Eleftherios Tsiamis and Christodoulos Stefanadis

First Department of Cardiology, Athens Medical School, Hippokration Hospital, Athens, Greece

Received 2 December 2004; accepted after revision 9 April 2005.

* Corresponding author. Tel.: +30 210 7782446; fax: +30 210 7485039. vbarberis{at}med.uoa.gr


    Abstract
 Top
 Abstract
 
We present two transesophageal echocardiographic images of a patient with acute myocardial infarction, demonstrating a large thrombus attached to the thoracic aortic wall, considered to be a complication of intra-aortic balloon pumping. The patient had received the device because of hemodynamic instability due to an infarct-related ventricular septal defect. Clinical manifestations which led to the diagnosis of thromboembolism were abdominal pain and deterioration of renal function, without signs of limb ischemia.

Keywords: Aortic thrombosis; Intra-aortic balloon pumping; Transesophageal echocardiography


A 65-year-old man with a history of smoking was admitted to a district hospital due to an extended anterior acute myocardial infarction. Twenty-four hours later, his hemodynamic condition deteriorated. A large, infarct-related apical ventricular septal defect was demonstrated by means of echocardiography, and the patient was referred to our hospital for further evaluation and treatment. An intra-aortic balloon pumping device (IABP) was inserted through the right femoral artery in order to stabilize the patient's hemodynamic status. The patient received adequate doses of intravenous heparin. Coronary artery angiography showed a severe proximal left anterior descending artery stenosis, whereas left ventriculography confirmed the ventricular septal defect and showed left ventricular dysfunction (ejection fraction 25–30%). The patient recovered quickly with IABP support. On the third day of his hospitalization, while awaiting cardiac surgery, he began experiencing light abdominal pain. A slight increase in plasma urea and creatinine levels occurred some hours later. Nevertheless, at this point there were no signs of hemodynamic instability or limb ischemia. Clinical status and renal function deteriorated gradually, requiring withdrawal of IABP under the suspicion of thromboembolism. Transesophageal echocardiography was then performed in order to evaluate the descending thoracic aorta. A large thrombus attached to the thoracic aortic wall was demonstrated (Figs. 1 and 2Go). Despite efforts for surgical treatment, the patient died some hours later in multi-organ failure condition.


Figure 1
View larger version (56K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 Transesophageal echocardiography of the descending thoracic aorta. Short axis view at 0° demonstrating a large thrombus (TH) protruding into the lumen of the aorta.

 


Figure 2
View larger version (61K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 2 Transesophageal echocardiography of the descending thoracic aorta. Long axis view at 80°. The illustrated thrombus (TH) seems to be extending 8cm along the thoracic aortic wall.

 

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?



This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Aggeli, C.
Right arrow Articles by Stefanadis, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aggeli, C.
Right arrow Articles by Stefanadis, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?