Skip Navigation

European Journal of Echocardiography 2003 4(4):320-326; doi:10.1016/S1525-2167(02)00172-5
© 2003 by European Society of Cardiology
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Hagendorff, A
Right arrow Articles by Becher, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hagendorff, A
Right arrow Articles by Becher, H
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2003, The European Society of Cardiology

Assessment of Regional Myocardial Hypoperfusion with Myocardial Contrast Echocardiography Using Intravenous Bolus Application in Patients with Acute Chest Pain: A Double Case Report

A Hagendorff1,*, A Goeckritz1, A Neugebauer1, T Rother1, T Linke2, D Pfeiffer1 and H Becher3

1Department of Cardiology–Angiology, University of Leipzig, Leipzig, Germany
2Department of Nuclear Medicine, University of Leipzig, Leipzig, Germany
3Department of Cardiology, University of Oxford, Oxford, UK

Received 21 August 2002; accepted after revision 5 December 2002.

* Address for correspondence: Andreas Hagendorff, Department of Cardiology–Angiology, University of Leipzig, Johannisallee 32, 04103 Leipzig, Germany. Tel: +49-341-97-12650; Fax: +49-341-97-12659. hages{at}medizin.uni-leipzig.de


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
Myocardial contrast echocardiography using power Doppler harmonic imaging is able to document myocardial hypoperfusion. Two case reports demonstrate the potential of intravenous bolus application of microbubbles in patients with acute chest pain due to myocardial ischaemia to detect regional low flow conditions. The case reports will focus on the necessity to present Doppler intensity kinetics by Doppler intensity vs time plots or coloured M-modes to present the data more objectively. In addition, the hypoperfusion detected with myocardial contrast echocardiography via bolus injection of microbubbles can only be proven by changes of regional perfusion between repetitive myocardial contrast echocardiography measurements or by additional perfusion analysis, e.g. by scintiscanning.

Keywords: power Doppler harmonic imaging; myocardial contrast echocardiography; contrast agent; myocardial perfusion; bolus injection


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
In just a couple of years, development of myocardial contrast echocardiography has revealed numerous methods to determine regional myocardial perfusion[1–7]. Power Doppler harmonic imaging uses a triggered image acquisition and a high mechanical index. In experimental series it could be demonstrated that qualitative, semi-quantitative, and quantitative analysis of regional myocardial perfusion is possible[1,8,9]. In clinical studies, interpretation of myocardial contrast echocardiography data was generally performed by analysis due to subjective criteria[10–14]. The main criticism for the usage of an intravenous bolus application is the dispersion of the microbubbles during the passage through the systemic veins, the right atrium, the right ventricle, and the pulmonary circulation. Thus, the input function is much wider than the transfer function in the myocardium. The gamma variate function, which has been shown to correlate with myocardial blood flow, is, however, only accurate when the bolus is not dispersed, such as those seen with left atrial or aortic root injections of micro-bubbles. Despite these theoretical considerations the present communication will focus on the potential of myocardial contrast echocardiography using rapid intravenous bolus application to detect regional myocardial hypoperfusion in clinical practice. This approach seems to be very suitable for myocardial perfusion analysis at rest in patients with acute coronary syndrome.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
The described power Doppler harmonic imaging measurements were performed with a System Five Performance Ultrasound System (GE Vingmed Ultrasound AS, Horten, Norway). Imaging was acquired in continuous second harmonic (octave) mode for conventional diagnostics, in intermittent coded harmonic angio mode for perfusion imaging with a standard phased array transducer which transmits ultrasound at a mean frequency of 1.5 MHz and receives it at 3.0 MHz. Ultrasound pulses were gated to end systole once every third cardiac cycle. The transmission power was set at maximum power. Mechanical index was 1.4. The transmit focus was set between 6 and 10 cm. A maximum dynamic range of 60 dB was used. Pulse repetition frequency was 3000 Hz. Gain compensations were optimized before injection of echocontrast agent. The settings of the ultrasound system during the power Doppler harmonic imaging measurements were as follows: compression 10 (according to the scale of the ultrasound system); dynamic range 6 (according to the scale of the ultrasound system); power –2 dB, gain –29 dB; pulse repetition frequency 3.00 kHz; frequency 1.5 MHz; sample volume 1.9 mm; low velocity reject 32.5 cm/s; colour gain –18 dB. Gain settings were reported in detail in a previously published study[15]. In this study a default setting was defined which worked in the majority of patients.

The data were digitally stored as cineloops and transferred after completion of the investigation to a standard Macintosh personal computer. Quantitative analysis of the data was performed using the Echo Pac 6.2b.134 software. After storage of the cineloops, myocardial regions of interest with a size of 3x3 to 7x7 pixels were defined. To illustrate the Doppler intensity kinetics, the traces of each regions of interest are shown in a logarithmic scale with Doppler intensity of the acoustic power in dB on the y-axis and time in seconds on the x-axis. Coloured M-modes crossing the interventricular septum also show the alterations of the septal opacification during the intravenous bolus application. Parametric imaging using the coloured M-modes reveals additional semi-quantitative or qualitative aspects for detection of hypoperfusion. Firstly, early ‘patchy patterns’ defined as small regions of the myocardium without opacification 10–20 s after the peak maximum Doppler intensity value can be observed. Secondly, the non-uniformity of Doppler intensity-attenuation in the apical, mid and/or basal areas of the myocardium seems to be characteristic for regional hypoperfusion. Thirdly, differences of myocardial opacification between corresponding myocardial areas, e.g. using the four-chamber view Doppler intensity-kinetics of the interventricular septum vs Doppler intensity-kinetics of the lateral wall can be used for the interpretation of regional hypoperfusion[15].

Intravenous bolus application was performed by a rapid injection of 0.3–0.5 ml Optison® (Mallinckrodt GmbH, Hennef, Germany) into a cubital or a forearm vein directly followed by a rapid flush of 5 ml saline. The dosage of Optison® was pre-tested because the peak maximum Doppler intensity of the ventricular cavity has to be 50 dB or higher to achieve sufficient opacification of the myocardium. The semi-quantitative analysis of regional perfusion after this standardization of the bolus application was only possible if cardiac output was in normal range according to the data of previous investigations[15]. Velocity time integral, heart rate, ejection fraction and cardiac output were measured by two-dimensional and pulsed Doppler echocardiography. Cardiac output has to be between 4.5 and 5.5 l/min and ejection fraction between 45 and 55% to be able to interpret the power Doppler harmonic imaging data. A low cardiac output results in a reduction of the Doppler intensity wash-in mainly due to the prolonged circulatory transit time and global hypoperfusion, but not due to regional myocardial hypoperfusion. On the other hand, the Doppler intensity wash-out would be prolonged due to the same reason.


    Case Report 1
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
A 52-year-old patient was referred immediately after the onset of acute chest pain. Arterial hypertension was the only cardiovascular risk factor. Electrocardiogram (ECG) showed ST elevation in the Wilson leads V2–V4 (see Fig. 1(e)). Laboratory tests including troponin T were normal. Coronary angiography was performed immediately after admission. During the preparations for coronary angiography transthoracic echocardiography was performed documenting mid-apical septal hypokinesis without wall thinning. Fig. 1(a–d) shows the perfusion analysis using myocardial contrast echocardiography with power Doppler harmonic imaging. An impaired regional myocardial blood flow in the apical septal region was observed (pronounced difference of the Doppler intensity-kinetics during the wash-out between the apical septal and apical lateral regions). An 80% stenosis of the left anterior descending artery (see Fig. 1(f,g) was found in coronary angiography. The lesion was successfully stented. One day after the intervention the patient complained of chest pain again. ECG showed negative T waves (see Fig. 2(e)). Troponin T was 0.015 µmol/l (normal range <0.01 µmol/l). Myocardial contrast echocardiography investigation showed an impaired regional myocardial blood flow in the apical septal region similar to that seen in the previous investigation (see Fig. 2(a–d)). Repeat coronary angiography did not show any stenosis or spasm (see Fig. 2(f,g)). Thus, at this moment a relevant impairment of regional septal microcirculation—presumably due to micro emboli after intervention—has to be considered. Eight days after intervention, the patient had no complaints and ECG was normal. Another myocardial contrast echocardiography revealed normal perfusion (Doppler intensity-kinetics—especially the wash-out of the apical septal and lateral areas show no differences) (see Fig. 3). Two-dimensional echocardiography performed 10 days after intervention showed no regional wall abnormalities.


Figure 1
View larger version (93K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 Power Doppler harmonic imaging measurement of regional myocardial perfusion in a patient with acute chest pain directly before diagnostic angiography using intravenous bolus application of Optison®. (a) Regions of interest located into the left ventricular (yellow), the apical septum (green) and the apical lateral wall (red) in a colour-coded two-dimensional image using power Doppler harmonic imaging. The side-by-side comparison of the Doppler intensity kinetics between apical septal and apical lateral regions as well as the Doppler intensity kinetic of the left ventricular cavum is illustrated in (b). (c) The colour-coded two-dimensional image with a colour M-mode axis through the right ventricle, the septum and the left ventricle, as well as the lateral wall. (d) The corresponding colour M-mode. Early ‘patchy patterns’ were found in the septum, whereas the lateral wall is homogeneously opacified. (e) The ECG tracings at hospital admission. (f,g) The result of the angiography (LAO and RAO projection) documenting a significant stenosis of the left anterior descending artery.

 


Figure 2
View larger version (87K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 2 Power Doppler harmonic imaging measurement of regional myocardial perfusion in the same patient featured in Fig. 1 one day after successful PTCA of the significant LAD stenosis using intravenous bolus application of Optison®. Regions of interest located into the left ventricular (yellow), the apical septum (green) and the apical lateral wall (red) in a colour-coded two-dimensional image using power Doppler harmonic imaging. The side-by-side comparison of the Doppler intensity kinetics between apical septal and apical lateral regions, as well as the Doppler intensity kinetic of the left ventricular cavum, is illustrated in (b). The colour-coded two-dimensional image with a colour-M-mode axis through the right ventricle, the septum and the left ventricle, as well as the lateral wall. (d) The corresponding colour-M-mode. Early ‘patchy patterns’ can still be observed in the septum, whereas the lateral wall is again homogeneously opacified. (e) The ECG tracings on the day after successful intervention. (f,g) The result of the second control angiography (LAO and RAO projection) excluding any restenosis or thrombosis of the epicardial vessels.

 


Figure 3
View larger version (94K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 3 Power Doppler harmonic imaging measurement of regional myocardial perfusion in the same patient featured in Figs. 1 and 2Go eight days after successful PTCA of the significant LAD stenosis using intravenous bolus application of Optison®. Regions of interest located into the left ventricular (yellow), the apical septum (green) and the apical lateral wall (red) in a colour-coded two-dimensional image using power Doppler harmonic imaging. The side-by-side comparison of the Doppler intensity kinetics between apical septal and apical lateral regions, as well as the Doppler intensity kinetic of the left ventricular cavum, is illustrated in (b). The colour-coded two-dimensional image with a colour-M-mode axis through the right ventricle, the septum and the left ventricle, as well as the lateral wall. (d) The corresponding colour-M-mode. The Doppler intensity wash-out of the septal areas is now similar to that of the comparable lateral wall regions and shows no differences. (e) The normalized ECG tracings 8 days after intervention.

 

    Case Report 2
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
A 65-year-old female patient was admitted because of an episode of central chest pain 2 days before admission to hospital. Her risk factors include obesity, arterial hypertension and non-insulin dependent diabetes. The ECG suggested septal wall ischaemia (see Fig. 4(g,h)). Laboratory tests were normal except for elevated blood glucose and glutamic-oxalacetic transaminase. Blood gas analysis documented moderate metabolic acidosis. Immediately before angiography echocardiography was performed showing akinesis with wall thinning in the mid-apical septal area. Fig. 4(a,b and d) show the results of the power Doppler harmonic imaging assessment: severe hypoperfusion in the apical and mid septal areas as well as the apex were found (a pronounced difference of the Doppler intensity-kinetics during the wash-out between the apical septal and apical lateral regions was present). Coronary angiogram, however, demonstrated normal vessel morphology of epicardial arteries (see Fig. 4(e,f)). A thallium scan performed on the same day showed hypoperfusion in the same areas (see Fig. 4(c)). Repeat echocardiography 1 week after angiography showed persisting akinesis of the septum. With respect to all findings, spontaneous lysis of an occluding LAD clot has to be assumed.


Figure 4
View larger version (84K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 4 Power Doppler harmonic imaging measurement of regional myocardial perfusion in a patient with chest pain since 2 days at admission to hospital using intravenous bolus application of Optison®. (a) The colour-coded two-dimensional image of the apical four-chamber view of a power Doppler harmonic imaging measurement with respective regions of interest put into the left ventricular cavum (yellow), the apical septum (green), and the apical lateral wall (red). In addition, the axis of the colour-M-mode given in (b) is shown. (c) The corresponding scintiscanning of the four-chamber view given in (a) documenting hypoperfusion in the apical and mid inferoseptal area as well as the apex. (d) The Doppler intensity kinetics of the regions of interests is given in (a). The Doppler intensity-signals of the septal areas are below the saturation threshold much earlier than those of the lateral wall. Coronary angiography documented normal epicardial arterial vessels (see (e,f)). (g,h) The ECG tracings of the patient.

 

    Discussion
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
Myocardial contrast echocardiography using power Doppler harmonic imaging can detect regional myocardial hypoperfusion in experimental and clinical settings. The most important problem of intravenous application is the spreading of the microbubble bolus due to its dispersion in the pulmonary circulation. Thus, the input function of the microbubbles into the myocardium is longer than the transfer function through the heart[2,10]. In clinical practice, however, a standardized intravenous bolus application seems to be suitable to detect regional myocardial hypoperfusion with myocardial contrast echocardiography using power Doppler harmonic imaging[15]. The reason why contrast defects appear earlier during the wash-out of contrast from the myocardium is that the concentration of microbubbles in the hypoperfused areas—which is lower than that of normal perfused areas—gets below the saturation threshold of the ultrasound system sooner than the normally perfused regions. The gamma variate function predicts also for microbubbles a delayed wash-out of contrast from hypoperfused areas like indicators used during myocardial scintiscanning. Because the reduction of the Doppler intensity signal is pronounced in hypoperfused areas, the effect of the early fall below the saturation threshold during the wash-out due to a low microbubble concentration in hypoperfused areas seems to be more important for the reduction of the Doppler intensity-signals than the delayed wash-out of the micro-bubbles. It can be assumed that the difference in myocardial contrast enhancement between apical and lateral wall was due to different microbubble concentration. The Doppler intensities of regions of interest in the left ventricular cavity in the proximity of the explored myocardium were not significantly different. In both cases there are convincing arguments that the Doppler intensity differences in the myocardium are due to hypoperfusion: in case 1 regional Doppler intensity-kinetics were normalized after normalization of the patient's complaint as well as the ECG recording; in case 2 hypoperfusion was confirmed by thallium scan. There are limited data published on normal perfusion patterns in myocardial contrast echocardiography. However, for the method we used normal perfusion patterns have been published in septal areas.

As illustrated by the figures, myocardial contrast echocardiography with power Doppler harmonic imaging using a standardized intravenous bolus application is able to detect regional apical hypoperfusion by significant differences of the Doppler intensity kinetics. The observed apical hypoperfusion can be due to a significant stenosis or other reasons of low flow conditions (see Figs. 1 and 2Go).

The Doppler intensity wash-in seems also to be suitable to estimate regional myocardial perfusion if the injection protocol is standardized using a prolonged uniform bolus as shown in cardiac magnetic resonance tomography[15]. A semi-quantitative analysis of the first pass of contrast agent after a standardized prolonged bolus application is established in cardiac magnetic resonance imaging for the evaluation of regional myocardial perfusion[16]. In these studies the signal intensity slope in the myocardium was correlated to the slope observed in the left ventricular cavity. It was shown that a high cardiac output and ejection fraction result in an acceleration of the slopes. Therefore, for follow-up studies it is important that cardiac output does not significantly differ because the slope of contrast kinetics depends on cardiac output.

The intravenous bolus application is able to become a clinically applicable technique because bolus injections are simpler and more convenient than setting up a contrast infusion. However, off-line analysis is time-consuming at present. Acquisition of the myocardial contrast echocardiography data requires about 90 s. It is possible to assess the recordings frame by frame in the laboratory. The data are much easier to interpret by post-processing analysis. Using coloured M-mode, diagnosis can be made within a few minutes, the Doppler intensity kinetics, however, take longer.

Both cases illustrate that the presentation of the Doppler intensity-kinetics or of a coloured M-mode is necessary to demonstrate the myocardial contrast echocardiography result more objectively. A single frame of a two-dimensional power Doppler harmonic imaging image cannot be convincing and is not sufficient for the documentation of a perfusion measurement with myocardial contrast echocardiography after an intravenous bolus injection of micro-bubbles. Myocardial contrast echocardiography with power Doppler harmonic imaging is limited by several facts, especially using intravenous bolus application. It is well known that myocardial contrast echocardiography is limited in basal segments. However, it is rare that only basal segments are involved. Power Doppler harmonic imaging is generally applicable in other apical views. However, in the two- and three-chamber view drop-outs due to rib shadowing are more frequent.


    Conclusion
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 
The intravenous bolus application of contrast is feasible and suitable for non-invasive monitoring of regional myocardial perfusion in patients with acute coronary syndromes. The potential of myocardial contrast echocardiography with power Doppler harmonic imaging to detect regional hypoperfusion seems to be similar to cardiac magnetic resonance imaging using intravenous bolus application of contrast agents with triggered imaging[16].


    Acknowledgements
 
The authors are grateful to A. Golding, S. Herrmann, B. Müller, A. Nägler and A. Ruschel for their technical assistance.


    References
 Top
 Abstract
 Introduction
 Methods
 Case Report 1
 Case Report 2
 Discussion
 Conclusion
 References
 

  1. Kaul S. Myocardial contrast echocardiography—15 years of research and development. Circulation (1997) 96:3747–3760.[Web of Science]
  2. Lindner J.R., Skyba D.M., Goodman N.C., et al. Changes in myocardial blood flow volume with graded coronary stenosis: an experimental evaluation using myocardial contrast echocardiography. Am J Physiol (1997) 272:H567–H575.[Web of Science][Medline]
  3. Hirooka K., Miyatake K., Hanatani A., et al. Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of levovist: application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques. Int J Cardiol Imaging (2000) 16:233–246.[CrossRef]
  4. Wei K., Skyba D.M., Fierschke C., et al. Interaction between microbubbles and ultrasound: in vitro and in vivo observations. J Am Coll Cardiol (1997) 29:1081–1088.[Abstract]
  5. Heinle S.K., Noblin J., Goree-Best P., et al. Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress—comparison with 99mTc-Sestamibi SPECTimaging. Circulation (2000) 102:55–60.[Abstract/Free Full Text]
  6. Rocchi G., Kasprzak J.D., Galema T.W., et al. Usefulness of power Doppler contrast echocardiography to identify reperfusion after acute myocardial infarction. Am J Cardiol (2000) 87:278–282.[CrossRef][Web of Science]
  7. Senior R., Kaul S., Soman P., et al. Power Doppler harmonic imaging: a feasibility study of a new technique for the assessment of myocardial perfusion. Am Heart J (2000) 139:245–251.[Web of Science][Medline]
  8. Linka A.Z., Sklenar J., Wei K., et al. Assessment of transmural distribution of myocardial perfusion with contrast echocardiography. Circulation (1998) 98:1912–1920.[Abstract/Free Full Text]
  9. Wei K., Jayaweera A.R., Firoozan S., et al. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion? J Am Coll Cardiol (1998) 32:252–260.[Abstract/Free Full Text]
  10. Firschke C., Lindner J.R., Wei K., et al. Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent. Circulation (1997) 96:959–967.[Web of Science][Medline]
  11. Kaul S., Senior R., Dittrich H., et al. Detection of coronary artery disease with myocardial contrast echocardiography. Comparison with 99mTc-Sestamibi single-photon emission computed tomography. Circulation (1997) 96:785–792.[Abstract/Free Full Text]
  12. Lepper W., Hoffmann R., Kamp, et al. Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angiography in patients with acute myocardial infarction. Circulation (2000) 101:2368–2374.[Abstract/Free Full Text]
  13. Lindner J.R., Villanueva F.S., Dent J.M., et al. Assessment of resting perfusion with myocardial contrast echocardiography: theoretical and practical considerations. Am Heart J (2000) 139:231–240.[Web of Science][Medline]
  14. Masugata H., Cotter B., Peters B., et al. Assessment of coronary stenosis severity and transmural perfusion gradient by myocardial contrast echocardiography. Circulation (2000) 102:1427–1433.[Abstract/Free Full Text]
  15. Hagendorff A., Göckritz A., Wunderlich A., et al. Determinants of myocardial hypoperfusion analyzed for the interventricular septum using power Doppler harmonic imaging with contrast echocardiography in humans—a methodological approach for clinical practice. J Am Soc Echocardiogr (2002) 15:404–415.[CrossRef][Web of Science][Medline]
  16. Al-Saadi N., Nagel E., Gross M., et al. Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance. Circulation (2000) 101:1379–1383.[Abstract/Free Full Text]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
A Hagendorff, A Werner, D Pfeiffer, and H Becher
Estimation of vasodilator response by analysis of Doppler intensity kinetics with myocardial contrast echocardiography using an intravenous standardized bolus administration
Eur J Echocardiogr, August 1, 2004; 5(4): 272 - 283.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Hagendorff, A
Right arrow Articles by Becher, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hagendorff, A
Right arrow Articles by Becher, H
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?