Copyright © 2005, The European Society of Cardiology
New generation 3-dimensional echocardiography for left ventricular volumetric and functional measurements: Comparison with cardiac magnetic resonance
Department of Cardiology, Academic Unit, The University of Hull, Castle Hill Hospital, Castle Road, Cottingham, Kingston-upon-Hull HU16 5JQ, UK
Received 15 March 2005; received in revised form 21 September 2005; accepted after revision 30 September 2005.
* Corresponding author. Tel.: +44 1482 624144; fax: +44 1482 624071.
n.p.nikitin{at}hull.ac.uk
| Abstract |
|---|
Aims Non-invasive assessment of left ventricular (LV) structure and function is important in the evaluation of cardiac patients. This study was designed to test the accuracy and reproducibility of new generation 3-dimensional echocardiography (3DE) in measuring volumetric and functional LV indices as compared with current "gold standard" of non-invasive cardiac imaging, cardiac magnetic resonance (CMR).
Methods and results Sixty-four subjects with good acoustic windows, including 40 cardiac patients with LV ejection fraction (EF)<45%, 14 patients with EF>45% and 10 normal volunteers underwent 3DE using a commercially available Philips Sonos 7500 scanner equipped with a matrix phase-array x4 xMATRIX transducer, and CMR on a 1.5T Signa CV/i scanner (GE Medical Systems). Volumetric assessment was performed with analytical 4D-LV-Analysis software (TomTec) for 3DE and MRI-Mass software (Medis) for CMR.
We found no significant differences in LV end-diastolic volume (EDV), end-systolic volume (ESV) and EF with excellent correlations between the indices measured using 3DE and CMR (r=0.97, r=0.98, and r=0.94, respectively). Bland–Altman analysis showed bias of 7ml for EDV, 3ml for ESV and –1% for EF with 3DE with corresponding limits of agreement (2SD) of 28ml, 22ml and 10%, respectively. Intraobserver and interobserver variabilities were for EDV: 3% and 4% (3DE) vs 2% and 2% (CMR), for ESV: 3% and 6% (3DE) vs 2% and 3% (CMR), and for EF: 4% and 4% (3DE) vs 2% and 4% (CMR), respectively.
Conclusion New generation 3DE provides accurate and reproducible quantification of LV volumetric and functional data in subjects with good acoustic windows as compared with CMR.
Keywords: Imaging; Echocardiography; Left ventricular function; Magnetic resonance imaging
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
K.Y. E. Leung and J. G. Bosch Automated border detection in three-dimensional echocardiography: principles and promises Eur J Echocardiogr, February 6, 2010; (2010) jeq005v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. C. Kim, D. M. Yang, W. Jin, and S. H. Lee Relation Between Total Renal Volume and Renal Function: Usefulness of 3D Sonographic Measurements With a Matrix Array Transducer Am. J. Roentgenol., February 1, 2010; 194(2): W186 - W192. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Bhan, S Kapetanakis, and M J Monaghan Three-dimensional echocardiography Heart, January 15, 2010; 96(2): 153 - 163. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Muraru, L. P. Badano, G. Piccoli, P. Gianfagna, L. Del Mestre, D. Ermacora, and A. Proclemer Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography Eur J Echocardiogr, January 6, 2010; (2010) jep217v2. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ren, J.-W. Tian, X.-P. Leng, H.-M. Wang, Y. Wang, and Z.-Z. Wang Assessment of Global and Regional Left Ventricular Function After Surgical Revascularization in Patients With Coronary Artery Disease by Real-time Triplane Echocardiography J. Ultrasound Med., September 1, 2009; 28(9): 1175 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Mor-Avi, L. Sugeng, and R. M. Lang Real-Time 3-Dimensional Echocardiography: An Integral Component of the Routine Echocardiographic Examination in Adult Patients? Circulation, January 20, 2009; 119(2): 314 - 329. [Full Text] [PDF] |
||||
![]() |
H. C. Kim, D. M. Yang, S. H. Lee, and Y. D. Cho Usefulness of Renal Volume Measurements Obtained by a 3-Dimensional Sonographic Transducer With Matrix Electronic Arrays J. Ultrasound Med., December 1, 2008; 27(12): 1673 - 1681. [Abstract] [Full Text] [PDF] |
||||
![]() |
S J Copley and T P Mathew Advances in echocardiography Imaging, September 1, 2006; 18(3): 160 - 165. [Abstract] [Full Text] [PDF] |
||||





