Skip Navigation

European Journal of Echocardiography 2005 6(5):336-343; doi:10.1016/j.euje.2004.11.004
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Schuster, P.
Right arrow Articles by Faerestrand, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schuster, P.
Right arrow Articles by Faerestrand, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2004, The European Society of Cardiology

Assessment of regional timing of left ventricular systolic longitudinal movement by Doppler tissue synchronization imaging in structurally normal hearts

Peter Schuster*, Knut Matre and Svein Faerestrand

Department of Heart Disease and Institute of Medicine, Haukeland University Hospital and University of Bergen, N-5021 Bergen, Norway

Received 25 May 2004; .

peter.schuster{at}med.uib.no

* Corresponding author. Tel.: +47 5597 2220; fax: +47 5597 5150.


   Abstract

Aims

To study the feasibility of a new semiautomatic echocardiographic modality called Tissue Synchronization Imaging (TSI) for measurement of the longitudinal left ventricular (LV) movement.

Methods and results

TSI was used in 20 subjects with structurally normal hearts to measure the time aspect of the regional longitudinal LV systolic movement in the apical four chamber view. Inter- and intraobserver agreement and the beat to beat variation were tested and compared to previously manually measured peak systolic delay (PSD) between the interventricular septum (IS) and the lateral free wall (LFW) at basal and mid LV, respectively (n = 19). TSI showed acceptable reproducibility and close correlation to manually measured PSD. The TSI method did not show false synchronous regional LV movement when synchrony was defined as a PSD <±25 ms. After minor adjustment of the TSI interval, 76.9% of the synchronous LV patterns in basal LV were correctly classified as compared to manual measurements.

Conclusions

The TSI method is accurate for clinical screening to reveal synchrony. At the present development the TSI method is not accurate enough to quantify regional systolic LV asynchrony, and still manual measurement of PSD is mandatory.

Keywords: Echocardiography Doppler ultrasound; Tissue velocity imaging; Left ventricle; Systole; Synchronicity


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.