Skip Navigation

European Journal of Echocardiography 2003 4(4):279-285; doi:10.1016/S1525-2167(03)00009-X
© 2003 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Moreno, R.
Right arrow Articles by Macaya, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moreno, R.
Right arrow Articles by Macaya, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2003, The European Society of Cardiology

Isovolumic Contraction Time by Pulsed-Wave Doppler Tissue Imaging in Aortic Stenosis

R. Moreno, J. Zamorano, C. Almería, J. A. Pérez-González, L. Mataix, J. L. Rodrigo, D. Herrera, A. Aubele, L. Pérez de Isla, E. De Marco, L. Sánchez-Harguindey and C. Macaya

Laboratory of Echocardiography, Hospital Clinico San Carlos, Madrid, Spain

Received 24 September 2002; accepted after revision 22 January 2003.


   Abstract

Background: Doppler Tissue Imaging (DTI) has been evaluated in ischaemic heart disease and some cardiomyopathies. In patients with aortic stenosis (AS), left ventricular contraction is slowered. This study aimed to evaluate the possible role of the measurement of isovolumic contraction time (ICT) by DTI in the evaluation of AS severity.

Methods: The study population constitutes 30 patients: 15 with AS (nine severe and six non-severe) and 15 control subjects. All of them had normal systolic function, sinus rhythm, and absence of ischaemic heart disease of conduction abnormalities. ICT was defined as the time from the onset of the QRS complex to the beginning of the DTI systolic wave. The correlation between ICT and aortic area obtained by continuity equation, as well as the diagnostic value of ICT in the identification of severe AS were studied.

Results: ICT was significantly increased in patients with severe AS (98±27 versus 65±21 ms, p=0.024). There was a significant correlation between ICT and aortic area (r=–0.56; p=0.035). The receiver operator characteristic curve of ICT in the identification of severe AS yielded an area under the curve of 0.852 (95% confidence interval: 0.665–1.0). The two best cut-points were <73 ms (88% sensitivity, 77% specificity) and <85 ms (78% sensitivity, 83% specificity). A value of <41 ms had a 100% sensitivity, but only a 17% specificity, and <91 ms showed a 100% specificity, but only a 44% sensitivity.

Conclusions: ICT measured by pulsed-wave DTI is increased in patients with aortic stenosis.

Keywords: aortic stenosis; Doppler tissue imaging


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
HeartHome page
F Bauer, F Mghaieth, N Dervaux, E Donal, G Derumeaux, A Cribier, and J-P Bessou
Preoperative tissue Doppler imaging differentiates beneficial from detrimental left ventricular hypertrophy in patients with surgical aortic stenosis. A postoperative morbidity study
Heart, November 1, 2008; 94(11): 1440 - 1445.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
P. Lindqvist, A. Waldenstrom, G. Wikstrom, and E. Kazzam
Potential use of isovolumic contraction velocity in assessment of left ventricular contractility in man: A simultaneous pulsed Doppler tissue imaging and cardiac catheterization study
Eur J Echocardiogr, August 1, 2007; 8(4): 252 - 258.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.