Skip Navigation

European Journal of Echocardiography 2000 1(1):32-41; doi:10.1053/euje.2000.0004
© 2000 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by D'hooge, J.
Right arrow Articles by Sutherland, G.R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by D'hooge, J.
Right arrow Articles by Sutherland, G.R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2000, The European Society of Cardiology

High Frame Rate Myocardial Integrated Backscatter. Does this Change our Understanding of this Acoustic Parameter?

J. D'hooge1,*, B. Bijnens2, F. Jamal2, C. Pislaru2, S. Pislaru2, J. Thoen3, P. Suetens1, F. Van de Werf2, C. Angermann4, F.E. Rademakers2, M.-C. Herregods2 and G.R. Sutherland{dagger},2

1Medical Image Computing, Department of Electrical Engineering, K.U. Leuven, Belgium
2Department of Cardiology, K.U. Leuven, Belgium
3Laboratorium voor akoestiek en thermische fysica, Department of Physics, K.U. Leuven, Belgium
4Department of Cardiology, Klinikum Innenstadt, University of Munchen, Germany


   Abstract

Aims: Integrated backscatter (IB) and its cyclic variation (CV) derived from radio-frequency (RF) data have been used as parameters to attempt myocardial tissue characterization. Prior imaging systems used to measure IB and its CV typically acquired data at frame rates of 20–30 Hz and at a resolution of 6–8 bits. If changes in IB levels are in part related to specific short-lived events, occurring within the cardiac cycle, this frame rate and resolution could have been too low to resolve adequately what might be a more complex data set.

Methods and Results: To investigate this possibility, we acquired real time two-dimensional (2D) myocardial IQ data (the ‘in-phase quadrature’ sampled RF data) at high frame rate (>100 Hz), high dynamic resolution (theoretical 19-bit) and a sector angle of 20°. Several consecutive heart cycles of myocardial data were acquired from individual cardiac walls in five closed chest dogs and 10 healthy, young volunteers at normal heart rates. On the reconstructed RF data regions of interest were indicated, and IB and its CV were calculated.

The extracted high frame rate curves showed that the CV of IB is not a smooth sinusoidal-like curve, but is made up of multiple reproducible peaks and troughs with local minima and maxima which are temporally related to active or passive mechanical events, i.e. systolic contraction, early ventricular relaxation and ventricular filling due to atrial contraction.

Conclusions: This study shows that increasing the rate of real-time RF data acquisition results in a more complex, reproducible IB curve. The resolved maxima and minima in IB levels are related to specific phases of the myocardial contraction. Furthermore, spectral analysis showed that IB curves acquired at normal heart rates contain information up to 40 Hz. Hence, cardiac imaging data sets used to analyse regional myocardial function obtained at frequencies lower than 80 frames per second can contain aliased information.

Keywords: Cyclic variation; Integrated backscatter; Temporal resolution; Tissue characterization


* Correspondence address: Jan D'hooge, UZ Gasthuisberg, Department of Cardiology, Herestraat 49, B-3000 Leuven, Belgium.

{dagger} G. R. Sutherland is a Visiting Professor of Cardiology at the K.U. Leuven.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
A. Micari, M. Pascotto, A. R. Jayaweera, J. Sklenar, N. C. Goodman, and S. Kaul
Cyclic variation in ultrasonic myocardial integrated backscatter is due to phasic changes in the number of patent myocardial microvessels.
J. Ultrasound Med., August 1, 2006; 25(8): 1009 - 1019.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
J.E Hancock, J.C Cooke, and M.J Monaghan
Effect of harmonic imaging on the measurement of ultrasonic integrated backscatter and its interpretation in patients following myocardial infarction
Eur J Echocardiogr, June 1, 2004; 5(3): 189 - 195.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
F. Weidemann, F. Jamal, G. R. Sutherland, P. Claus, M. Kowalski, L. Hatle, I. De Scheerder, B. Bijnens, and F. E. Rademakers
Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate
Am J Physiol Heart Circ Physiol, August 1, 2002; 283(2): H792 - H799.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Hatle and G. R. Sutherland
Regional myocardial function--a new approach.
Eur. Heart J., August 1, 2000; 21(16): 1337 - 1357.
[PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.